Echelon I/O Model Reference for Smart Transceivers and Neu Manual do Utilizador Página 182

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 209
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 181
172 Timer/Counter Output Models
If the output is disabled, the new (non-zero) output starts immediately
after t
fout
For a new output value of zero, the output is disabled immediately and
not at the end of the current cycle
A disabled output is a logic 0 by default, unless the invert keyword is used in the
I/O object declaration.
ONE CYCLE
NEW OUTPUT
APPEARS ON PIN
HARDWARE
UPDATED
INTERNALLY
START
OF
io_out()
ONE CYCLE
TIME
PULSEWIDTH
OUTPUT
t
fout
t
ret
Timer/Counter 1
Timer/Counter 2
IO10
IO9
IO8
IO0
IO1
IO2
IO3
IO4
IO5
IO6
IO7
High Current Sink Drivers for 3100 Family Devices
IO11
System Clock
Divide Chain
Figure 64. Pulsewidth Output and Timing
Table 64. Pulsewidth Output Latency Values for Series 3100 Devices
Symbol Description Typical at 10 MHz
t
fout
Function call to output update 101 μs
t
ret
Return from function 13 μs
Vista de página 181
1 2 ... 177 178 179 180 181 182 183 184 185 186 187 ... 208 209

Comentários a estes Manuais

Sem comentários