Neuron C Reference Guide 51
Function Description
io_in( ) Input data from I/O object:
Dualslope input
Edgelog input
Infrared input
Magcard input
Neurowire I/O slave mode
Neurowire I/O with invert
option
Serial input
Touch I/O
Wiegand input
others
io_in_ready( ) Event function which evaluates to
TRUE when a block of data is available
from the parallel I/O object
io_in_request( ) Start dualslope A/D conversion
io_out( ) Output data to I/O object:
Bitshift output
Neurowire I/O slave mode
Neurowire I/O with invert
option
Serial output
Touch I/O
others
io_out_ready( ) Event function which evaluates to
TRUE when a block of data is available
from the parallel I/O object
io_out_request( ) Request ready indication from parallel
I/O object
io_preserve_input( ) Preserve first timer/counter value after
reset or io_select( )
io_select( ) Set timer/counter multiplexer
io_set_baud( ) Set the serial bit rate for an sci I/O
object