Neuron Tools Errors Guide 13
LCL# Description
7
The encoded value for the device's clock input of <id> is not within the
supported range of <min> to <max> [LCL#7]
An invalid encoded clock value has been used to describe the hardware
clock speed. See LCL#2.
8
The encoded value for the channel's minimum clock rate of <id> is not within
the supported range of <min> to <max> [LCL#8]
An invalid encoded clock value has been specified for the channel's
minimum clock speed. This value originates from the standard transceiver
database, and the presence of this problem indicates a corrupted or
incorrect database record. Verify that your standard transceiver database
(stdxcvr.xml) has not been corrupted. Re-install the product and choose the
Repair option when prompted.
9
Unable to compute media access control values (raw transceiver data): the
specified Neuron clock frequency is too high for the transceiver [LCL#9]
This error condition is unavoidable for some combinations of (typically)
high Neuron clock rates and (typically) slow channels. A different
operating mode of the same transceiver or a lower Neuron clock rate might
solve the problem.